VMware Updated Nov 26, 2026

Disable 10GbE NIC Pre-Check in the VCF 9.0 Installer

1 min read

Disable 10GbE NIC Pre-Check in the VCF 9.0 Installer

The VCF 9.0 Installer checks that the ESXi management interface uses a 10GbE adapter and blocks the deployment if it does not. In VCF 5.x you could skip this only through the Cloud Builder API. VCF 9.0 has an easier lab-only way that works with both the Installer UI and API. SSH to the VCF Installer as vcf, switch to root with su -, append enable.speed.of.physical.nics.validation=false to /etc/vmware/vcf/domainmanager/application.properties, then restart services with sddcmanager_restart_services.sh. Run the pre-check again and the NIC speed check is gone. Broadcom does not support this.

My Deploying a Minimal VCF 9.0 Lab post puts this NIC speed bypass together with the other lab shortcuts, and VCF 9.0 Minimum Requirements for a Lab lists vCPU, RAM and storage per component.

Source: Disable 10GbE NIC Pre-Check in the VCF 9.0 Installer by William Lam (williamlam.com, June 2025).


Broadcom Social Media Advocacy

VMware Social Media Advocacy

Daniel Micanek, VMware vExpert. Virtualization, VCF, NSX and Kubernetes notes from the lab and the field.